Home / All / Reinforcement Refractory Steel fiber /

W- 304 Hooked end Steel Fiber

W- 304 Hooked end Steel Fiber

W- 304 Hooked end Steel Fiber
W- 304 Hooked end Steel FiberW- 304 Hooked end Steel FiberW- 304 Hooked end Steel FiberW- 304 Hooked end Steel FiberW- 304 Hooked end Steel Fiber
CategoriesReinforcement Refractory Steel fiber
BrandHARVEST Refractory Manufacturer
ModelW-304/30/.40HE
Length30mm
Equivalent Diameter0.4mm
ShapeHooked ends
Cross-sectional area shapeRound
Tensile strength1400Mpa min
Aspect ratio75
FOB portDalian / Xingang / Bayuquan / Yingkou
Terms of PaymentL/C, D/A, D/P
Update TimeMar 19,2024
Detail Information

Harvest’s “W-series” Steel Fibre Product Data Sheet

 

W-304/30/.40HE

 

  

Harvest’s “W-series” fibres are cold drawn wire fibres for refractories materials for the high temperature processing industries (Metallurgy, petrochemical, cement, glass, power station and other furnaces).

 

 

Chemical Analysis (%):

 

Alloy No.

Cr

Ni

C≤

Si≤

Mn≤

P≤

S≤

304

24-26.00

19-22.00

0.08

1.5

2.0

0.045

0.030

 

*Other materials :430/304/330/316…& low carbon steel  can be manufactured specifically to suit customer’s requirements.

 

  

Service Temperature:

 

Melting Point

Recommended Maximum Service Temperature

304

1380-1455℃

Cyclic Heating

1000℃

Continuous Service

850℃

 

 

Dimensions: 

  • Lengths are 6/10/15/25/30/50/60mm. Other lengths can be manufactured specifically to suit customer’s requirements.

  • Equivalent diameter 0.2/0.4/0.5/0.6/0.75/1.0mm. Other diameters can be manufactured specifically to suit customer’s requirements.

 

Packing: 

  • Fibres are packed in 1/5/10/20kg cartons then put on pallets. Other packaging can be supplied if requested.

Using method and using quantity: 

  • Usually use 0.2-2% ( volume ) of steel fiber in refractories or concrete materials, mixed evenly to maximize the use effect of steel fiber into full play. Mix method :1. Wet mix; 2. Dry mix.
  • In order to prevent  explosions & radiation for concrete buildings , it is recommended to use steel fibres number 40-60% (volume).

Health & Safety:

  • USING STEEL FIBRES UNDER NORMAL CONDITIONS DOES NOT PRESENT AN INHALATION, INGESTION OR CONTACT HEALTH HAZARD.

  • BECAUSE OF THEIR PHYSICAL NATURE, WE RECOMMEND THAT OPERATIVES HANDLING THE FIBRES SHOULD ALWAYS WEAR GLOVES.

  • TO AVOID DETERIORATION OF PACKING, THE FIBRES SHOULD BE STORED IN A DRY ENVIRONMENT.

TO AVOID DETERIORATION OF PACKING, THE FIBRES SHOULD BE STORED IN A DRY ENVIRONMENT.

.jpg

.jpg

.jpg

235095-1301150P34930_.jpg

Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
About HARVEST
Company Profile
Dalian Harvest Metal Fibers Co., Ltd. is a Sino-France joint venture company , a specialty in producing thermal resistant steel fibers, and steel fibers for concrete reinforcement. HARVEST steel fibers have been well adopted by a wide range of professionals, such as Metallurgy, Cement, Petrol refinery, Chemistry, Ceramics, and so on. Steel fibers have been well used in concrete construction projects, such as  bridges, tannels, high ways, airport,  power stations, industrial floors. More than 90% of HARVEST steel fibers have been used by our customers in Asia, Europe, North and South America,  Australia, etc… . HARVEST has been winning the users high praise because of high quality products and good services.

subscription
QR code